PRODUCTS Products
Monitor system
项目名称: AN5800
担保机构: AN5800 monitoringsystem is a highly reliable and fully digitalized system developed by ANRY and allows Mod-bus communication. It adopts advanced technology andis designed in accordance with high standard requirement that has been in online operation for a long time, wit... 还款方式: AN5800 monitoringsystem is a highly reliable and fully digitalized system developed by ANRY and allows Mod-bus communication. It adopts advanced technology andis designed in accordance with high standard requirement that has been in online operation for a long time, with high reliability, strong ability of resisting disturbance and good compatibility.Thesystem has dual redundancy broad power supply as hot backup for each other; each module has independent isolated power module. The arrangement of high-power components (power and relay) on back plug board and signal processing and host machine on front plugboard providesrelatively independent property and increases the ability of resisting disturbance, allowing the system to be more stable, reliable and safer when it is in operation, and to meet the requirement of API670 standard.Ithas analog signal interface, like 4-20mA and buffer output interfaces, digital communication interface and Mod-bus communication interface. User may monitor a lot of information including the real time running data and status in all channels, alarm setup point, full scale range, alarm status and alarm event list, which allow user to keep an eye on the status of system and control its running.Thereare two specifications for the system to meet different user requirements: 19″ standard rack, supporting 18 channels at most, and 14″ small rack, supporting 12 channels at most.Easy configuration and useAN5800-CFG configurationcontrol software can perform exact and rapid configuration to AN5800 system, fully improving the manufacturer’s productivity. It displays the real time value and status of all channels of the system inmany forms (bar graph, list, curve), readily for configuration and easyfor user to monitor the working status of units.Independent mode or network modeAN5800 system can work under the independent mode, or together with multiple AN5800 racks through network.PropertiesAN5800 monitoring system:l Full digitalization design: better stability;l Plug board design, (19’’ rack with 9 function modules and 18 channels, 14’’ rack with 6 function modules and 12 channels);l Redundancy design: dual power as hot backup for each other, DPDT relay;l Isolationdesign: (each module has independent working power supply, communication bus separated from the power supply), to increase the capacity of resisting disturbance;l Mod-bus communication interface (bus-based RS-485);l Panel display: 4-digit display window and LED light indicating status;l Configuration and calibration on site. System configurationRequired components ModelAN5800/90AN5800/99AN5800-CFGNamePower moduleSystem rackConfiguration softwareSystem requirementsRequiredRequiredRequiredFunctionSystem power supplySystem bus, rackSystem configurationRedundant dual power19’’ standard rackParameter configurationHot backup for each other14’’ small rackReal time monitoring  Optional components ModelAN5800/10AN5800/20AN5800/30AN5800/40AN5800/50AN5800/80NameVibration moduleShaft Position moduleSpeed moduleAxis eccentric moduleThermal Expansion moduleKey-phase moduleSystem requirementsOptionalOptionalOptionalOptionalOptionalOptionalFunctionBearing vibrationShaft PositionSpeedEccentricityThermal expansionKey-phaseShaft vibrationdifferential expansion Over-speedKey-phaseLow frequency bearing vibrationMachine lifting amountZero speedThrow
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-10
担保机构: AN5800/10series vibration monitoring module receives signals from two magneto-electric tachometric sensors or Proximity sensors; the original signals from the sensor are converted into digital signals by asignal interface unit; the digital signals are transmitted to an embedded microcontro... 还款方式: AN5800/10series vibration monitoring module receives signals from two magneto-electric tachometric sensors or Proximity sensors; the original signals from the sensor are converted into digital signals by asignal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device vibration.2. Purposel Online monitoring and protection of rotary machine bearing vibration;l Online monitoring and protection of rotary machine shaft vibration;l Online monitoring and protection of rotary machine Throw.3. Functionsl Digital display unit: To display real-time value;l Serialcommunication interface: Parameter configuration and digital signal buscommunication through AN5800 / CFG configuration software;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: The front panel BNC connector and rear terminal buffer output (Sensor original signal) are convenient to connect the data acquisition system to collect dynamic signals.4.Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l Use forward board and back board plug-in module type structure design, after the board (power supply andrelay output) and the former board (signal processing, the host) physical isolation, through case motherboard more redundant connectors (needle) in parallel connection, stable and reliable.5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind);l Metallurgy (steel mills and aluminium manufacturers, etc.);l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.);l Cement;l Papermaking;l Mine (coal and iron mines);l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Motorsl Water pumps;l Gearboxsl Water turbines;l Air blowers;l Coal-breaker;l Coal-mill;l Rotary machines like fans.6. Technical Specifications l Sensors:Magneto-electric Velocity sensor: Inertial sensor, no power supplySensitivity: 20 mV/mm/S(500mV/in/s).Piezoelectric acceleration sensor:ICP type, 24V / 4mA constant current source power supplySensitivity: 100mV/gPiezoelectric velocity sensor:ICP type, 24V / 4mA constant current source power supplySensitivity: 4mV/gProximity sensor: φ8 probeSensitivity: 7.87mV/μm (200mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.l Range of measurement:Displacement: 0~999μm(Pk-Pk); Resolution: 1μm; Precision: 0.5%±1μm.Velocity: 0~99.9mm/S(rms); Resolution: 0.01mm/S; Precision: 0.5%±0.01mm/S.Acceleration: 0~9.99g(Pk); Resolution: 0.01g; Precision: 0.5%±0.01g.l The frequency rangePiezoelectric Sensor: 0.5~15KHz;Magneto-electric Sensor:Standard: 10~1000HzLow frequency: 5~1000Hz  Ultra-low frequency: 0.5~100Hz;Proximity Sensor:0~10 KHz;l Power supply of module:DC supply: 24VDC (18~36V);Module power dissipation: less than 5Wl Standard signal output:Standard current, active 4~20mA (responding to the upper limit of full range;Driving load: ≤750ΩValid transmission distance: ≤ 300 meters(1000 feet)l Relay output:Two-level high(Alert,Danger)programmable setup and normally open/closed dry contact output, available for setting full range, error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, 1A/220VAC; double-pole double-throw (DPDT);Alarm time delay: 0.1~60S, default value: 0.5S;Alarm latching: programmable setup, (non- latching by default).l Physical property:Before the board: Size: 248(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.6kg.After the board: Size: 128(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.3kg.l Environmental restrictions:Operating temperature: 30℃~+65℃(-22oF~+150 oF)Storage temperature: -40℃~+85℃(-40oF~+180 oF)Relative humidity: 0~95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670;Safety certificate: C E;Anti-electromagnetic interference: EMC\ LVD;Refer to EN55011\ EN 61010\EN50081\EN50082 7. Ordering informationAN5800/11/12/13—bearing vibration/shaft vibration/throwAN5800/11-AXX-BXX-CXX-DXXAN5800/12-AXX-BXX-CXX-DXXAN5800/13-AXX-BXX-CXX-DXXStandard Configuration Model:Bearing vibration:AN5800/11-00-01-00-00(velocity sensor input, velocity output)AN5800/11-00-00-00-00(velocity sensor input, displacement output)Bearing vibration:(ultralow frequency)AN5800/11-00-01-02-00(velocity sensor input, displacement output)AN5800/11-00-00-03-00(displacement sensor input, displacement output)Shaft vibration:AN5800/12-00-00-01-00Throw: AN5800/13-00-03-01-00A: Channel selection:00—2 channel01—1 channel (channel A on top of module by default)B: Measurement type:00—Displacement:0~999μm(Pk-Pk)01—Velocity:0~99.9mm/s (rms)02—Acceleration:0~9.99g(Pk)03—Throw:0~999μm(Pk-Pk)C: Type of external sensor:00—AN1930 velocity sensor01—AN1808 proximity sensor (φ8 probe)02—AN1931 frequency velocity sensor03—AN1931 frequency displacement sensor04—AN1940 piezoelectric acceleration sensor (ICP)05—AN1940 piezoelectric velocity sensor (ICP)D: Relay output selection (DPDT)00—3 relays output(Alert、Danger、Not-ok)01—2 relays output(Alert、Danger)02—1 relay(Alert)03—No relay output
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-20
担保机构: AN5800/20 series Shaft Position monitoring module receives signals from two Proximitysensor; the original signals from the sensor are converted into digitalsignals by a signal interface unit; the digital signals are transmittedto an embedded microcontroller unit (MCU), and are then id... 还款方式: AN5800/20 series Shaft Position monitoring module receives signals from two Proximitysensor; the original signals from the sensor are converted into digitalsignals by a signal interface unit; the digital signals are transmittedto an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device Shaft Position or differential expansion.2. Purposel Online monitoring and protection of rotary machine shaft position;l Online monitoring and protection of rotary machine expansion difference.3. Functionsl Digital display unit: To display real-time value;l Serialcommunication interface: Parameter configuration and digital signal buscommunication through AN5800 / CFG configuration software ;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: The front panel BNC connector and rear terminal buffer output (Sensor original signal) are convenient to connect the data acquisition system to collect dynamic signals.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embedded microcontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l Use forward board and back board plug-in module type structure design, after the board (power supply andrelay output) and the former board (signal processing, the host) physical isolation, through case motherboard more redundant connectors (needle) in parallel connection, stable and reliable.5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Water pumps;l Air blowers;l Rotary machines like Water turbines.6. Technical Specificationsl sensors:Proximity sensor: Proximity probe: Φ8 /Φ11 /Φ25 /Φ50 probeShaft position Sensitivity:2mm: 7.87mV/μm (200mV/mil)4mm: 3.94 mV/μm (100mV/mil)25mm: 0.394 mV/μm (10mV/mil)Expansion difference Sensitivity:12mm: 0.787mV/μm (20mV/mil)25mm: 0.394 mV/μm (10mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.l Range of measurement:Shaft position: 2.00/4.00mm; Resolution: 0.01mm; Precision: 0.5%±0.01mm.Expansion difference: 12.00/25.00mm; Resolution: 0.01mm;Precision: 0.5%±0.01mm.l Power supply:DC supply: 24VDC (18-36V);Overall power consumption: Less than 5W.l Standard signal output: Standard currentActive 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, 1A/220VAC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Before the board: Size: 248(L) ×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.6kg.After the board: Size: 128(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.3kg.l Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering informationAN5800/21/22- Shaft position/ Expansion differenceAN5800/21- AXX-BXX-CXX-DXX-EXX-FXXAN5800/22- AXX-BXX-CXX-DXX-EXX-FXXStandard Configuration Model:Shaft position:AN5800/21-00-00-00 (assorted with AN1808 sensor)AN5800/21-01-00-00 (assorted with AN1811 sensor)AN5800/21-03-03-00 (assorted with AN1850 sensor)Expansion difference:AN5800/22-00-02-00 (assorted with AN1825 Proximity Sensor)AN5800/22-00-03-00 (assorted with AN1825 Proximity Sensor)A: The channel number00—2 channel 01-- 1 channel (channel A on top of module by default)B: Sensor type:00-- AN1808 Proximity sensor(φ8 probe)01--AN1811 Proximity sensor(φ11 probe)02-- AN1825 Proximity sensor(φ25 probe)03-- AN1850 Proximity sensor(φ50 probe)xx--OthersC: Relay output (DPDT):00—Three relay dry contact output (high - low - Alert, high high - low low- Danger, Not-ok)01--Double relay dry contact output (high - low - Alert and high high - low low- Danger)02--Single relay dry contact output (high - low - Alert or high high - low low- Danger)03-- Double relay dry contact output (high - Alert and high high - Danger)04--No relay output
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-30
担保机构: AN5800/30series speed monitoring module receives signals from two magneto-electric sensors, Magneto-resistive sensors or Proximity sensors; the original signals from the sensor are converted into digitalsignals by a signal interface unit; the digital signals are transmittedt... 还款方式: AN5800/30series speed monitoring module receives signals from two magneto-electric sensors, Magneto-resistive sensors or Proximity sensors; the original signals from the sensor are converted into digitalsignals by a signal interface unit; the digital signals are transmittedto an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device Speed.2. Purposesl Online monitoring and protection of rotary machine speed; l Zero-speed survey control;l Over-speed protection.3. Functionsl Digital display unit: To display real-time value;l Serialcommunication interface: Parameter configuration and digital signal buscommunication through AN5800 / CFG configuration software ;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Bufferinterface: The front panel BNC connector and rear terminal buffer output (Sensor original signal) are convenient to connect the data acquisition system to collect dynamic signals.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l Useforward board and back board plug-in module type structure design, after the board (power supply and relay output) and the former board (signal processing, the host) physical isolation, through case motherboard more redundant connectors (needle) in parallel connection, stable and reliable;l High/low velocity measuring systems implement precision measurement of zero and low (turning) speed.5. Application        Application Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.        Monitored equipment:l Steam turbines;l Compressors;l Water pumps;l Water turbines;l Air blowers;l Coal breakers;l Electromotor;l Rotary machines like fans.  6. Technical Specificationsl Sensors:Magneto-electric sensor (AN1920): Passive, outputting pulse signals changing with speed frequency;Mounting clearance: 1mm±0.2mm.Magneto-resistive sensor (AN1910):Passive, outputting TTL level signals changing with speed frequency;Mounting clearance: 2.0mm±0.5mm.Proximity sensor: AN1808 Φ8 probeSensitivity: 7.87mV/μm (200mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.Note: Mountingclearance is determined based on a 1mm mechanical distance between tooth crest and probe or -10VDC output voltage of preamplifier; mechanical distance is firstly considered so as to prevent the probe from being damaged due to the eccentric shaft.l Measuring rangeOver-speed protection/standard speed:Range: 0-9999rpmPrecision: ±0.5%±1 rpmZero speed:Range: 0-99.99rpmPrecision: ±0.5%±0.01 rpmNote: Range can be set by field programming.l Power supply:DC supply: 24VDC (18-36V);Overall power consumption: Less than 5W.l Standard signal output:Active 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, 1A/220VAC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Before the board: Size: 248(L) ×40(W)× 262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.6kg.After the board: Size: 128(L) ×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.3kg.l Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670;Safety certificate: C E;Anti-electromagnetic interference: EMC\ LVD;Refer to EN55011\ EN 61010\EN50081\EN500827. Ordering informationAN5800/31/32- Speed/Zero speedAN5800/31- AXX-BXX-CXX-DXXAN5800/32- AXX-BXX-CXX-DXXStandard Configuration Model:Speed/Over-speed:AN5800/31-00-00-60-00 (assorted with AN1920 sensor)AN5800/31-00-01-60-00 (assorted with AN1910 sensor)AN5800/31-00-02-03-00 (assorted with AN1808 Proximity sensor)Zero speed:AN5800/32-00-01-60-00 (assorted with AN1910 Sensor)AN5800/32-00-02-03-00 (assorted with AN1808 Proximity Sensor)A: The channel number00—2 channel01-- 1 channelB: Sensor type:00--AN1920 passive magneto-electric sensor01--AN1910 active magneto-resistive sensor02--AN1808 Proximity sensor (φ8 probe)C: Tooth number (key or slot number)01--160--60XX--Others (represented by a figure)D: Relay output (DPDT):00—Three dry contact output (Alert, Danger, Not-ok)01--Double dry contact output (Alert, Danger)02--Single dry contact output (Alert)03--No relay output
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-40
担保机构: AN5800/40Axis eccentric monitoring module receives signals from two Proximity sensor (Axis eccentric and Key-phase); the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontrol... 还款方式: AN5800/40Axis eccentric monitoring module receives signals from two Proximity sensor (Axis eccentric and Key-phase); the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoringand protection of device Axis eccentric.2. Purposesl Online monitoring of rotary machine Axis eccentric; l Online monitoring of rotary machine phase.3. Functionsl Digital display unit: To display real-time value;l Serialcommunication interface: Parameter configuration and digital signal buscommunication through AN5800 / CFG configuration software ;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Bufferinterface: The front panel BNC connector and rear terminal buffer output (Sensor original signal) are convenient to connect the data acquisition system to collect dynamic signals.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l Useforward board and back board plug-in module type structure design, after the board (power supply and relay output) and the former board (signal processing, the host) physical isolation, through case motherboard more redundant connectors (needle) in parallel connection, stable and reliable.5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Air blowers;l Other rotary machines6. Technical Specificationsl Sensors:Proximity sensor: Proximity sensor: Φ8 probeSensitivity: 7.87mV/μm (200mV/mil), 2mm rangeOutput voltage: -2 ~ -18VDC;GAP voltage: -10VDC.Note: keyphase and eccentricity need to install an Proximity sensor, respectively output key trust and eccentricity signal to module's eccentric channel and key link.l Range of measurement:Eccentricity: 0 ~999μm; Resolution: 1μm; Precision: 0.5%±1μm.Phase Output: square signal (TTL)l Power supply:DC supply: 24VDC (18-36V);Overall power consumption: Less than 5W.l Standard signal output: Active 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, 1A/220VAC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Before the board: Size: 248(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.6kg.After the board: Size: 128(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.3kg.l Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering information Standard Configuration Model: AN5800/40- AXX-BXX-CXXAxis eccentric: AN5800/40-00-00-00Key-phase: AN5800/40-01-00-03A: The channel number00—2 channel (Axis eccentric and Key-phase) 01-- 1 channel (Use only as a key/B channel)B: Sensor type:00-- AN1808 Proximity sensor (φ8 probe)C: Relay output (DPDT):00—Three relay dry contact output (Alert, Danger, Not-ok)01--Double relay dry contact output (Alert, Danger)02--Single relay dry contact output (Alert)03-- No relay output
项目规模: 0 项目期限: 0 个月 年化收益:
10页次1/2首页Prev12Next尾页
4006-974-975
Copyright ©2005 - 2022  American ANRY Electron Corp.
犀牛云提供企业云服务
FOLLOW US: