PRODUCTS Products
Monitors
项目名称: AN3550
担保机构: AN3550 series speed monitoring receives signals from a magneto-electric tachometric sensor or Proximity sensor; the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are t... 还款方式: AN3550 series speed monitoring receives signals from a magneto-electric tachometric sensor or Proximity sensor; the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device speed.2. Purposesl Online monitoring and protection of rotary machine speed;l Zero-speed survey control;l Over-speed protection;l Key-phase signal output.3. Functionsl Highlight digital display unit: To display real-time vibration value;l Plate-type touch keyboard: Field programming parameter setting;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: Sensor original signal buffer output.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embedded microcontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l High/low velocity measuring systems implement precision measurement of zero and low (turning) speed.5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Water pumps;l Water turbines;l Air blowers;l Coal breakers;l Electromotor;l Rotary machines like fans.6. Technical Specificationsl Sensors:Magneto-electric sensor: Passive, outputting pulse signals changing with speed frequency;Mounting clearance: 1mm±0.2mm.Magneto-resistive sensor:Passive, outputting TTL level signals changing with speed frequency;Mounting clearance: 2.0mm±0.5mm.Proximity sensor: Φ8 probeSensitivity: 7.87mV/μm (200mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.Note:Mounting clearance is determined based on a 1mm mechanical distance between tooth crest and probe or -10VDC output voltage of preamplifier; mechanical distance is firstly considered so as to prevent the probe from being damaged due to the eccentric shaft.l Measuring rangeOver-speed protection/standard speed:Range: 0-9999rpmPrecision: ±0.5%±1 rpmZero speed:Range: 0-99.99rpmPrecision: ±0.5%±0.01 rpmKey phase:Output square (TTL) level signalNote: Range can be set by field programming.l Power supply:DC supply: 24VDC (18-36V);AC supply: 220VAC (185-260V)/47-63Hz;AC supply: 110VAC/47-63Hz;Overall power consumption: ≤ 5W.l Standard signal output:Active 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Boundary dimension: 160(W)×80(H)×120(D)mm  6.3(W)×3.15(H)×4.7(D)inWeight: 1kg.l Way of installation:Open hole installation:Hole size: 152 (W) × 76 (H) mm, 6.0(W) ×3.0(H)inl Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering informationAN3551/52/53- speed/zero speed/key phaseAN3551- AXX-BXX-CXX-DXX-EXX-F02-GXXAN3552- AXX-BXX-CXX-DXX-EXX-F02-GXXAN3553- AXX-BXX-CXX-DXX-EXX-F02-GXX Standard Configuration Model:Revolution speed: AN3551-00-00-00-00-00-02-60 (assorted with AN1920 sensor)Zero speed: AN3552-01-00-00-00-00-02-60 (assorted with AN1920 sensor)Key phase: AN3553-02-02-00-00-00-02-01 (assorted with AN1808 Proximity Sensor)A: Range limit00--0 ~ 9999rpm (standard)01--0 ~ 99.99rpm (zero speed)02--Square wave phase signal output (key phase)Note: Range can be set by field programming.B: Sensor type:00--AN1920 passive magneto-electric sensor01--AN1910 active magneto-resistive sensor02--AN1808 Proximity sensor (φ8 probe)xx--OthersNote:It is recommended that magneto-electric probe be used for over-speed/revolution speed/zero-speed protectors, with speed measurement of multi-tooth fluted disc, and active magneto-resistive or eddy-current probe be used for key-phase protector (φ8 probe).C: Relay output (DPDT):00--Double dry contact output (Alert, Danger)01--Single dry contact output (Alert)02--No relay outputD: Standard signal output:00--4 ~ 20mA standard current output01--1 ~ 5V standard voltage output02--RS 485 communication interface outputE: Power supply00--24VDC (18 ~ 36V)01--220VAC02--110VACF: Way of installation00--Guide rail installation DIN35mm01--Base plate installation02- Open hole installationG: Tooth number (key or slot number)01--160--60XX--Others (represented by a figure)Note: Please note if you select other options, If you have any questions, please consult the technical department.
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN3560
担保机构: AN3520 series shaft position monitoring receives signals from a Proximity sensor (shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then ident... 还款方式: AN3520 series shaft position monitoring receives signals from a Proximity sensor (shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device shaft position.2. Purposesl Online monitoring and protection of rotary machine shaft position; l Online monitoring and protection of rotary machine expansion difference;3. Functionsl Highlight digital display unit: To display real-time vibration value;l Plate-type touch keyboard: Field programming parameter setting;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: Sensor original signal buffer output.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l A key quickly sets the direction of the sensor(Stay away from the positive direction Or close to positive direction)l Intelligent fast initial zero setting, easy to debugl Digital quick debugging5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Water pumps;l Air blowers;l Rotary machines like Water turbines.6. Technical Specificationsl Sensors:Proximity sensor: Proximity probe: Φ8 /Φ11 /Φ25 /Φ50 probeShaft position:2mm: 7.87mV/μm (200mV/mil)4mm: 3.94 mV/μm (100mV/mil)25mm: 0.394 mV/μm (10mV/mil)Expansion difference:12mm: 0.787mV/μm (20mV/mil)25mm: 0.394 mV/μm (10mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.l Range of measurement:Shaft position: 2.00/4.00mm; Resolution: 0.01mm;Precision: 0.5%±0.01mm.Expansion difference: 12.00/25.00mm; Resolution: 0.01mm;Precision: 0.5%±0.01mm.l Power supply:DC supply: 24VDC (18-36V);AC supply: 220VAC (185-260V)/47-63Hz;AC supply: 110VAC/47-63Hz;Overall power consumption: ≤5W.l Standard signal output: Standard currentActive 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Boundary dimension: 160(W)×80(H)×120(D)mm  6.3(W)×3.15(H)×4.7(D)inWeight: 1kg.l Way of installation:Open hole installation:Hole size: 152 (W) ×76 (H) mm,  6.0(W)×3.0(H)inl Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering informationAN3561/62- Shaft position/ Expansion differenceAN3561- AXX-BXX-CXX-DXX-EXX-F02AN3562- AXX-BXX-CXX-DXX-EXX-F02Standard Configuration Model:Shaft position: AN3561-00-00-00-00-00-02 (assorted with AN1808 sensor)AN3561-01-01-00-00-00-02 (assorted with AN1811 sensor)AN3561-03-03-00-00-00-02 (assorted with AN1850 sensor)Expansion difference:AN3562-02-02-02-00-00-02 (assorted with AN1825 Proximity Sensor)A: Measuring range00—2.00m(φ5/φ8 probe) 01-- 4.00m(φ11 probe)02-- 12.00m(φ25 probe)03-- 25.00m(φ50 probe)xx--OthersB: Sensor type:00-- AN1808 Proximity sensor(φ8 probe)01--AN1811 Proximity sensor(φ11 probe)02-- AN1825 Proximity sensor(φ25 probe)03-- AN1850 Proximity sensor(φ50 probe)xx--OthersC: Relay output (DPDT):00--Double relay dry contact output (high - low - Alert and high high - low low- Danger)01--Single relay dry contact output (high - low - Alert or high high - low low- Danger)02-- Double relay dry contact output (high - Alert and high high - Danger)03--No relay outputD: Standard signal output:00--4 ~ 20mA standard current output00--1 ~ 5V standard voltage output02--RS 485 communication interface outputxx--OthersE: Power supply00--24VDC (18 ~ 36V)01--220VAC02--110VACxx--OthersF: Way of installation00-- DIN-rail mount: DIN35mm01-- Panel mount02-- Open hole installationNote: Please note if you select other options, If you have any questions, please consult the technical department.
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN3580
担保机构: AN3580 series dual vibration monitoring receives signals from two magnet-electrical vibration velocity Sensors(Bearing vibration) or Proximity sensors(shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are tran... 还款方式: AN3580 series dual vibration monitoring receives signals from two magnet-electrical vibration velocity Sensors(Bearing vibration) or Proximity sensors(shaft vibration);the original signals from the sensor are converted into digital signalsby a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device Vibration.2. Purposel Online monitoring and protection of rotary machine bearing vibration;l Online monitoring and protection of rotary machine shaft vibration;l Online monitoring and protection of rotary machine Throw.3. Functionsl Highlight digital display unit: To display real-time vibration value;l Plate-type touch keyboard: Field programming parameter setting;l Standard signal output: 4-20mA;l On-off output: two-stage alert normally open/closed contact output;l LED indicator: To display various statuses;l Buffer interface: Sensor original signal buffer output.4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Motorsl Water pumps;l Gearboxsl Water turbines;l Air blowers;l Coal-breaker;l Coal-mill;l Rotary machines like fans.6. Technical Specificationsl Sensors:Magneto-electric Velocity sensor: Inertial sensor, no power supply, Sensitivity: 20mV/mm/S (500mV/in/s).Piezoelectric acceleration sensor: ICP type, 24V / 4mA constant current source power supply Sensitivity: 100mV/gPiezoelectric velocity sensor: ICP type, 24V / 4mA constant current source power supply Sensitivity: 4mV/gProximity sensor: Φ8 probeSensitivity: 7.87mV/μm (200mV/mil)Output voltage: -2 ~ -18VDC;GAP voltage: -10VDC.l Range of measurement:Displacement: 0~999μm(Pk-Pk); Resolution: 1μm; Precision: 0.5%±1μm.Velocity: 0~99.9mm/S(rms); Resolution: 0.01mm/S; Precision: 0.5%±0.01mm/S.Acceleration: 0~9.99g(Pk); Resolution: 0.01g; Precision: 0.5%±0.01g.l The frequency range Piezoelectric Sensor: 0.5~15KHz;Magneto-electric Sensor:Standard: 10~1000HzLow frequency: 5~1000Hz  Ultra-low frequency: 0.5~100Hz;Proximity Sensor:0~10 KHz;l Power supply:DC supply: 24VDC (18-36V);AC supply: 220VAC(185-260V)/47-63Hz;AC supply: 110VAC/47-63Hz;Overall power consumption: ≤5W.l Standard signal output: Standard currentActive 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Boundary dimension: 160(W)×80(H)×120(D)mm  6.3(W)×3.15(H)×4.7(D)inWeight: 1.2kg.l Way of installation:Open hole installation:Hole size: 152 (W) × 76 (H) mm, 6.0(W) ×3.0(H)inl Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670;Safety certificate: C E;Protection level: IP56;Anti-electromagnetic interference: EMC\ LVD;Refer to EN55011\ EN 61010\EN50081\EN500827. Ordering informationAN3581/82/83—Bearing vibration / shaft vibration / Turbine throwAN3581- AXX-BXX-CXX-DXX-EXXAN3582- AXX-BXX-CXX-DXX-EXXAN3583- AXX-BXX-CXX-DXX-EXXStandard Configuration Model:Bearing vibration: AN3581-00-00-00-00-00Shaft vibration: AN3582-00-01-00-00-00Turbine throw: AN3583-00-01-00-00-00A: The monitor range:00—Displacement: 0~999μm(Pk-Pk)01—Velocity: 0~99.9mm/s(rms)02—Acceleration: 0~9.99g (Pk)B: External sensor type:00—Magneto-electric Velocity sensor01—Proximity Probe sensor( probe with φ8 or φ5 diameter)02—Ultra-low frequency magneto-electric speed sensor03—Piezoelectric acceleration sensor04—OtherC: Relay output( DPDT):00— 2 relay output(Alert, Danger)01— 1 relay output(Alert)02— No relay outputD: Standard signal output:00— 4~20mA standard current output01— 1~5V standard voltage output02— RS 485 communicate interface outputE: Power supplier:00—220VAC01—24VDC02—110VAC      03—OtherNote: Please note if you select other options, If you have any questions, please consult the technical department.
项目规模: 0 项目期限: 0 个月 年化收益:
8页次2/2首页Prev12Next尾页
4006-974-975
Copyright ©2005 - 2022  American ANRY Electron Corp.
犀牛云提供企业云服务
FOLLOW US: