PRODUCTS Products
Monitor system
项目名称: AN5800-50
担保机构: AN5800/50Thermal Expansion monitoring module receives signals from two LVDT sensor; the original signals from the sensor are converted intodigital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then ident... 还款方式: AN5800/50Thermal Expansion monitoring module receives signals from two LVDT sensor; the original signals from the sensor are converted intodigital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, thus implementing online monitoring and protection of device Thermal Expansion.2. Purposesl Online monitoring of rotary machine Thermal Expansion; l Online monitoring of Valve opening;3. Functionsl Digital display unit: To display real-time value;l Serialcommunication interface: Parameter configuration and digital signal buscommunication through AN5800 / CFG configuration software ;l Standard signal output: 4-20mA;l  On-off output: two-stage alert normally open/closed contact output;l  LED indicator: To display various statuses;l Bufferinterface: The front panel BNC connector and rear terminal buffer output (Sensor original signal) are convenient to connect the data acquisition system to collect dynamic signals. 4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embedded microcontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l  Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l Useforward board and back board plug-in module type structure design, after the board (power supply and relay output) and the former board (signal processing, the host) physical isolation, through case motherboard more redundant connectors (needle) in parallel connection, stable and reliable.5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Water pumps;l Air blowers;l Rotary machines like Water turbines.6. Technical Specificationsl Sensors: Linear Variable Differential Transformer (LVDT) : Sensitivity:  0-25mm, 400 mV /mm0-50mm, 200 mV /mmOutput voltage: 0 ~ 10VDC; l Range of measurement:0-25mm; Resolution: 0.01mm; Precision: 0.5%±0.01mm.0-50mm; Resolution: 0.01mm; Precision: 0.5%±0.01mm.l Power supply:DC supply: 24VDC (18-36V);Overall power consumption : Less than 5W.l Standard signal output:Active 4-20mA (corresponding to upper range)Drive load: ≤750ΩEffective transmission distance: ≤ 300m (1,000 feet).l Relay output:Two-stagethreshold (Alert, Danger) programmable setting, normally open/closed dry contact output, configurable whole range, with an error ≤0.1%;Insulation resistance: ≥1000MΩ;Contact capacity: 2A/30VDC, 1A/220VAC, double-pole double-throw (DPDT);Alarm-delay: 0.1-60S, default: 0.5S;Alert lock: Defaulting to non-locking.l Physical property:Before the board: Size: 248(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.6kg.After the board: Size: 128(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.3kg.l Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% non-freezing.l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering information Standard Configuration Model: AN5800/50- AXX-BXX-CXXThermal Expansion:AN5800/50-00-25-00AN5800/50-00-50-00A: The channel number00—2 channel 01— 1 channel (channel A on top of module by default)B: Sensor type:25— AN1950 LVDT sensor (0-25mm)50— AN1950 LVDT sensor (0-50mm)C: Relay output (DPDT):00—Three relay dry contact output (Alert, Danger, Not-ok)01—Double relay dry contact output (Alert, Danger)02—Single relay dry contact output (Alert)03—No relay output
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-80
担保机构: AN5800/80key-phase Monitoring module receives signals from two Magneto-resistivesensors or Proximity sensors; the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and ar... 还款方式: AN5800/80key-phase Monitoring module receives signals from two Magneto-resistivesensors or Proximity sensors; the original signals from the sensor are converted into digital signals by a signal interface unit; the digital signals are transmitted to an embedded microcontroller unit (MCU), and are then identified, judged, processed and compared by software and output by output units, BUF port output phase (TTL level) reference signal2. Purposel Vibration monitoring phase reference signall Axis eccentric monitoring phase reference signall Throw monitoring phase reference signal3. Functionl Front BNC port buffer outputl Terminal wiring buffer outputl Internal bus transmitted to the function module channel requiring key-phase signall Failure (Not ok) on-off outputl LED indicator: indicating the working condition of module4. Featuresl Perfectself-inspection and diagnosis function; when a failure occurs, current output is 0mA, and "Not Ok" LED on the panel is on;l Embeddedmicrocontroller unit (MCU); an E2PROM data storage unit (for important parameters) and a FLASH process program storage unit are integrated in the chip;l Power unit: a DC-DC/AC-DC module power supply realizes ultra-width power input and isolated output;l Useforward board and back board plug-in module type structure design, after the board (power supply and relay output) and the former board (signal processing, the host) physical isolation, through case motherboard more redundant connectors (needle) in parallel connection, stable and reliable.5. ApplicationApplication Fields:l Power plants (thermal, hydro, nuclear and wind)l Metallurgy (steel mills and aluminium manufacturers, etc.)l Petrochemical engineering (refining and chemical, coal chemical industry and chemical fertilizers, etc.)l Cementl Papermakingl Mine (coal and iron mines)l Hydraulic engineering (reservoirs and pump stations), etc.Monitored equipment:l Steam turbines;l Compressors;l Air blowers;l Other rotary machines6. Technical Specifications l Sensors:Magneto-resistive sensor (AN1910):Passive, outputting TTL level signals changing with speed frequency;Mounting clearance: 2.0mm±0.5mm.Power supply: +12VDC /20mA;Proximity sensor: AN1808 probeSensitivity: 7.87mV/μm (200 mV/mil);Output voltage: -2 ~ -18VDC;Power supply:-24VDC /20mA;GAP voltage: -10VDC.Note:Mounting clearance is determined based on a 1mm mechanical distance between tooth crest and probe or -10VDC output voltage of preamplifier; mechanical distance is firstly considered so as to prevent the probe from being damaged due to the eccentric shaft.l Signal output: TTL level signals.l Power supply:DC supply: 24VDC (18-36V);Overall power consumption: Less than 5W.l Measuring range:Output a pulse signal per circle (0~100 by default)Buffer output:Front BNC connector output and back terminal wiring output;Note: refer to descriptions of other modules if A way is of other function module.l Physical property:Before the board: Size: 248(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.6kg.After the board: Size: 128(L)×40(W)×262(H)mm;9.8(L)×1.5(W)×10.3(H)in;Weight: 0.3kg.l Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670;Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVD;Refer to EN55011\ EN 61010\ EN50081\EN50082.7. Ordering informationStandard Configuration Model: AN5800/80-AXX-BXX-CXXTwo- key phase:AN5800/80-03-00-03One- key phase:AN5800/80-00-00-00One- key phase:AN5800/80-01-00-00A: Channel selection:00—Shaft vibration and key-phase01—Throw and key- phase02—Axis eccentric and key -phase (AN5800/40 module)03—Double key- phaseB: Sensor selection:00—AN1808 proximity sensor (φ8 probe)01—AN1911 Magneto-resistive sensorC: Relay output selection (DPDT)00—3 relays output(Alert、Danger、Not-ok)01—2 relays output(Alert、Danger)02—1 relay(Alert)03—no relay output
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-90
担保机构: AN5800/90 powermodule has completely independent two-way redundant power supply, with each channel separately supplying the power required by the whole rack. It is installed on AN5800 system rack, supplying power to all function modules and communication bus.2. Module purposel Pr... 还款方式: AN5800/90 powermodule has completely independent two-way redundant power supply, with each channel separately supplying the power required by the whole rack. It is installed on AN5800 system rack, supplying power to all function modules and communication bus.2. Module purposel Provide stable and reliable working power to the system;l Provide isolated power to RS-485 communication bus.3. Module functionl Convert external power supply of different level into 24VDC voltage and supply it to all function modules;l Provide 5VDC power to RS-485 communication bus;l LED indicator light: indicate the working status of module.4. Technical specificationsl Power supply:AC:220VAC(85~260V);Frequency:47~63Hz;   AC:110VAC;DC:220VDC(125~370V);    DC:24VDC(18~36V);Rated power:≤120W.l Output power:Voltage:24VDC±0.5V;Voltage:5VDC (communication bus isolated power); Power:≤ 100W.l Physical property:Before the board: Size: 248(L)×60(W)×262(H)mm;9.8(L)×2.4(W)×10.3(H)in;Weight: 1.5kgAfter the board: Size: 128(L)×60(W)×262(H)mm;9.8(L)×2.4(W)×10.3(H)in;Weight: 0.5kg.l Environmental restrictions:Operating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.5. Ordering informationStandard Configuration Model: AN5800/90- AXX-BXXAN5800/90-01-00AN5800/90-01-02AN5800/90-01-01A: Channel selection00—Single power supply(not recommended)01—Dual power supplyB: Specification of voltage classes00—Two 220VAC power supply (compatible with 220VDC)01—Two 24VDC power supply02—One 220VAC and one 24VDC power supply03—Others
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-99
担保机构: AN5800/99 system rack isthe standard 19″or 14″ width and 6U height design, with 10 or 7 slots, capable of containing 9 or 6 standard function modules and 1 power module. It is designed in a way that the mother panel could be placed inthe middle in order for the front and back panels t... 还款方式: AN5800/99 system rack isthe standard 19″or 14″ width and 6U height design, with 10 or 7 slots, capable of containing 9 or 6 standard function modules and 1 power module. It is designed in a way that the mother panel could be placed inthe middle in order for the front and back panels to be inserted against each other into the mother panel and transmit power and data information through it.2.  Functionl Provide slot for all function modules and power module;l Communication bus mother panel.3.  Featuresl Material: aluminium magnesium alloy material, good quality of heat dispersion and strong ability resisting electromagnetic radiation;l Technology: electrostatic spraying technology is applied to the bearing to prevent scratches;l Shell color: White or black (grit) Oxidation drawing processl Design:module connector adopts redundancy design (usually connected in parallel when there are more than two pins) to ensure the reliability ofinterconnecting;l Compatibility: function module, with its good expansibility, could be freely inserted into the provided 9 or 6 slots. It is required to use the front and back plug board according to their different roles.4. Description of moduleAn AN5800/99 systemrack has a built-in mother panel, providing all function modules with the slots on front and back panels, which are inserted against each other into the slot of mother panel. The mother panel, as the passageway for signal, power supply and communication bus, provides 9 (6) 8TE (40mm) wide slots for function module slot and 1 12TE (60mm) wide slot for power module5.  Technical standardsl Physical property:Method of installation: tap the plate, fix the screw on panel:Outline size:(width*height*depth)482mm*266mm*360mm 19in*10.5in*14.2inTapping size:(width*height)448mm*266mm   17.6in*10.5inFixed installation size:(width*height)465mm*190mm    18.3in*7.5inMethod of installation: fixed panel(4 M6 screws)Weight: 5.5Kg(not including function module)l Environmental restrictionOperating temperature: -30℃ ~ +65℃ (-22oF ~ +150 oF);Storage temperature: -40℃ ~ +85℃ (-40oF ~ +180 oF);Relative humidity: 0 ~ 95% (non-condensing).l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP56;Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082. 6. Ordering informationStandard Configuration Model: AN5800/99- AXX-B00-C0019″ full rack: AN5800/99-00-00-0014″ full rack: AN5800/99-01-00-00A: Channel number selection00—19″,10 slots(9+1)01—14″,7 slots(6+1)Note: 19″ case: 84TE,8TE/per function mode, 12TE/per power module1TE=0.2″= 5.08mmB: Number of front blind plate (added)00—noneXX—N (the option here indicates the number)C: Number of back blind plate (added)00—noneXX—N (the option here indicates the number)
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN5800-CFG
担保机构: AN5800 system has RS485 serial communication interface and allows Modbuscommunication. It is fully digitalized and adopts multi-redundancy design for signal processing and power, with high reliability and strongability of resisting disturbance. It provides different functions available for sele... 还款方式: AN5800 system has RS485 serial communication interface and allows Modbuscommunication. It is fully digitalized and adopts multi-redundancy design for signal processing and power, with high reliability and strongability of resisting disturbance. It provides different functions available for selection depending on user’s need when delivered, and is configured by CFG configuration software.  2.FunctionAN5800-CFG system configuration software can be used to perform the following functions:l Upload and display the configuration information of all function modules of the systeml Display the real time data information collected by AN5800 system in list, bar and waveform graph for user to monitor the units.l Adopt the Mod-bus communication protocol conforming to international standard, support RS485 site bus-based serial communicationl Adopt windowed user interface, which is easy for user to handle and comprehend system configuration and how to use the software.3.  Description of main functionModule configurationAlarm latching;Alarm bypass;Alarm reset.Channel configurationAlarm setup (positive alarm, negative alarm);Protection setup (positive protection, negative protection);Full scale setup (positive full scale, negative full scale);System calibration.Test reportReal time value report monitoring;Real time value bar graph monitoring;History waveform graph;Alarm event;Channel utilization list.4. Operating environment of AN5800-CFGOperating system: Windows XP SP2, Window 2000 or higher;CPU:1GHz above;Memory:512MB above;Hard disc:20G above;CD Rom:CD-ROM;Graphics card:VGA, screen resolution 1280*768 above (1280*1024 recommended), color quality 32 bits.5. Ordering informationStandard Configuration Model: AN5800-CFG- AXXA: Communication cable and converter:00:RS485-USB communication cable and converter01:RS485-RS232 communication cable and converter02:RS485-USB and RS485-RS232 communication cable and converter
项目规模: 0 项目期限: 0 个月 年化收益:
10页次2/2首页Prev12Next尾页
4006-974-975
Copyright ©2005 - 2022  American ANRY Electron Corp.
犀牛云提供企业云服务
FOLLOW US: