PRODUCTS Products
Sensors
项目名称: AN1808
担保机构: 1. Overview: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1808 Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measur... 还款方式: 1. Overview: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1808 Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surface. It can notonly be used for static (shaft position) signal measurement, but also used for dynamic (shaft vibration) signal measurement. It is mainly usedfor the shaft vibration, shaft displacement, key phase, speed and eccentricity of film sliding bearing rotating machinery.AN18088mm proximity   Sensor system follows the 670 Standard made by AmericanPetroleum Institute (API) for this kind of Sensor completely. All AN1808 8mm proximity   Sensor systems can reach specified performance criteria and the probes, extension cables and proximitors are fully interchangeable, no independent matching or calibration is required. TheSensor system is safe and explosion-proof in essence and it will not cause spark under electrical operation.Proximitor AN18008mm proximitor has two types of mounting base plate. It can select DIN35mm guide rail or traditional panel for mounting. The base plate is insulating when either kind of mounting method is adopted and no separate insulating plate is required.AN18008mm proximitor housing is cast from aluminum. To shield external interference, the housing and the signal public terminal (signal earth) are connected inside the proximitor. As the mounting base plate and guide rail seat are made of insulating engineering plastics, it can be ensured that the proximitor housing and earth are isolated when a proximitor is mounted, the radio interference resistance ability is improved and the European RFI/EMI anti-radiation standards can be reached.AN1800 8mm proximitor uses Spring Loc terminal which can be fixed automatically, and wiring can be realized without erecting tools. Besides, it will not get loose for boltfixing is not required.Fault toleranceof AN1800 8mm proximitor: any wiring fault of supply terminal, common terminal (SG) and output terminal can not damage the proximitor, and it has the function of power polarity error protection and output short-circuit protection.Probe and extension cable Allparts of AN 1808 8mm probe are connected through mechanical deformationto ensure its stability and reliability in severe environment.Forall connectors of AN 1808 8mm probe and AN1880 extension cable, gold-plated copper connectors are adopted as per MIL-C-39012 (the military specification of the U.S.). These connectors only need to be fixed manually (connectors can be locked automatically), and special mechanical locking device can prevent loose connection.Connectorsat two ends of AN1880 extension cable are different. The connector withmale thread (adapter) is coupled to probe, while the connector with female thread is coupled to proximitor. Fluoroplastics resistant to highand low temperature and chemical corrosion are used for cable insulation and sheath.2. Technical Specificationsl Linear range: 2.0mm (80mil)Linear range is from the position about 0.25mm (10mil) from surface of the target: 0.25~2.3mm (10~90mil).l Sensitivity: 7.87mV/μm (200mV/mil)Thesensitivity is less than 7.87mV/μm (200mV/mil) ±5% within the linear range of 2.0mm (80mil) including interchangeability error.l Probe installation clearance: 1.25mm (50mil).l Frequency response:0~10KHz, typical value of 0~-3dB, 300m (1000 feet) field wiring.l Power supply:DC supply: -24VDC (-23~-26VDC);Power consumption: current consumption is no more than 20mA.l  Requirements for target:Diameterof target (width of toroid): 16mm (0.6in) not less than 2 times of diameter of probe head; calibrate it on site if the detected surface is small.Shaft diameter: minimum 50mm (2in), 76mm (3in) recommend; pay attention to installation distance between probes to avoid mutual effect when diameter is less than 50mm, and ensure the distance is no less than 40mm (1.6in).Calibration of target material: 40CrMo steel/AISI4140 steel; calibrate it if the target material is inconsistent.l Interchangeability error:Error of interchangeable probe of the same type is ≤±5%;Error of interchangeable extension cable of the same type is ≤±5%;Error of interchangeable proximitor of the same type is ≤±5%;l Field wiring:Using0.5~1.5mm2 three-core shield cable; distance between proximitor and probe is less than 300m (1000 feet). When using a longer cable, signal suffers from attenuation, which needs calibration on site.l Environmental limitations:Probe and extension cable:Probe head pressure: less than 12MPaTemperature: -50℃~+170℃(-58oF~+338 oF)Working medium: air, oil, water, ammonia hydroxide.Proximitor:Temperature: -35℃~+85℃(-31oF~+185 oF)  Relative humidity: 0~95% (non-condensing) l Physical characteristics:Probe head material: PPS - PPS engineering plastics material resistant to high temperature;Probe housing material: AISI 304 stainless steel (SST);Probe housing torque: standard directly installed probe: 15N.mReversely installed probe: 7.5 N.mExtension cable: 75Ω coaxial cable (covered by fluoroplastic insulating sheath);Armoring of probe and extension cable: 304 SST stainless steel;Proximitor material: A308 aluminum;System length: 5m or 9m including extension cable;Minimum turn radius of cable: 25mm (1in);Connector material: gold-plated brass.l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP65;Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4 Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.3. Ordering informationl AN1808 8mm standard proximity probe Metric system: AN1808/M   M10x1 threadAN1808/M-AXX-BXX-CXX-DXX-EXXBritish system: AN1808/I   3/8″-24UNF threadAN1808/I-AXX-BXX-CXX-DXX-EXXStandard model:AN1808/M-00-05-10-00-00AN1808/M-00-05-50-00-00AN1808/M-00-05-90-00-00AN1808/I-00-05-10-00-00AN1808/I-00-05-50-00-00AN1808/I-00-05-90-00-00A: Unthreaded length00—0mm / 0 in05—5mm/ 1/4 in10—10mm/ 1/2 inIncrease by 10mm (0.5in) progressively when placing an order.Max. unthreaded length shall be 20mm/0.8in less than length of probe housing;Min. unthreaded length is 0, max. housing length minus 1in;B: Total housing length (including unthreaded length):05—50mm / 2 in10—100mm/4 in03-30mm/ 1.2in (housing size of reversely installed probe)Total housing length is increased by 10mm/0.5in progressively;Max. housing length is 250mm/10in and min. is 25mm/1in.C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - unarmored01 - armoredE: Approval institution00 - no requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – otherl AN1808 8mm reversely installed proximity probe Metric system: AN1808/MR M10x1 thread; unthreaded length: 5mm; total housing length: 30mm.AN1808/MR-05-30-CXX-DXX-EXXBritish system: AN1808/IR 3/8″-24UNF thread; unthreaded length: 0.2in; total housing length: 1.2in.AN1808/IR-02-12-CXX-DXX-EXXStandard model:AN1808/MR-05-30-10-00-00AN1808/MR-05-30-50-00-00AN1808/MR-05-30-90-00-00AN1808/IR-02-12-10-00-00AN1808/IR-02-12-50-00-00AN1808/IR-02-12-90-00-00C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - unarmored01 - armoredE: Approval institution00-No requirement01-ATEX: Ⅱ1 G Exia ⅡC T4       XX - other l AN1800 8mm proximitorAN1800-08-BXX-CXX-DXXStandard model:AN1800-08-05-00-00AN1800-08-09-00-00B: total cable length (probe + extension cable)05—5m09—9mC: installation mode00 - DIN35mm guide rail installation01 – Base plate installationD: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other l AN1880 extension cableAN1880-AXX-BXX-CXXStandard model:AN1880-40-00-00AN1880-80-00-00A: cable length40—4m45—4.5m80—8m85—8.5mB: cable options00 - Unarmored01 - ArmoredC: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX –Other
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN1811
担保机构: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1811  Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surfa... 还款方式: Sensor system Components of AN1808 8mm proximity Sensor system:l AN1811  Probe ;l AN1880 Extension cable;l AN1800 8mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surface. It can notonly be used for static (shaft position) signal measurement, but also used for dynamic (shaft vibration) signal measurement. It is mainly usedfor the shaft vibration, shaft displacement, key phase, speed and eccentricity of film sliding bearing rotating machinery.AN1811 11mmproximity   Sensor system follows the 670 Standard made by American Petroleum Institute (API) for this kind of Sensor completely. All AN1811 11mm proximity   Sensor systems can reach specified performance criteria and the probes, extension cables and proximitors are fully interchangeable, no independent matching or calibration is required. TheSensor system is safe and explosion-proof in essence and it will not cause spark under electrical operation.Proximitor AN180011mm proximitor has two types of mounting base plate. It can select DIN35mm guide rail or traditional panel for mounting. The base plate is insulating when either kind of mounting method is adopted and no separate insulating plate is required.AN180011mm proximitor housing is cast from aluminum. To shield external interference, the housing and the signal public terminal (signal earth) are connected inside the proximitor. As the mounting base plate and guide rail seat are made of insulating engineering plastics, it can be ensured that the proximitor housing and earth are isolated when a proximitor is mounted, the radio interference resistance ability is improved and the European RFI/EMI anti-radiation standards can be reached.AN1800 11mm proximitor uses Spring Loc terminal which can be fixed automatically, and wiring can be realized without erecting tools. Besides, it will not get loose for boltfixing is not required.Fault toleranceof AN1800 11mm proximitor: any wiring fault of supply terminal, common terminal (SG) and output terminal can not damage the proximitor, and it has the function of power polarity error protection and output short-circuit protection.Probe and extension cable Allparts of AN 1811 11mm probe are connected through mechanical deformation to ensure its stability and reliability in severe environment.For all connectors of AN 1811 11mm probe and AN1880 extension cable, gold-plated copper connectors are adopted as per MIL-C-39012 (the military specification ofthe U.S.). These connectors only need to be fixed manually (connectors can be locked automatically), and special mechanical locking device can prevent loose connection.Connectors at two ends of AN1880 extension cable are different. The connector with male thread (adapter) is coupled to probe, while the connector with female thread is coupled to proximitor. Fluoroplastics resistant to highand low temperature and chemical corrosion are used for cable insulation and sheath.2. Technical Specificationsl Linear range: 4.0mm (160mil)Linear range is from the position about 0.50mm (20mil) from surface of the target: 0.50~4.50mm (20~200mil). l Sensitivity: 3.94mV/μm (100mV/mil)Thesensitivity is less than 3.94mV/μm (100mV/mil) ±5% within the linear range of 4.0mm (160mil) including interchangeability error. l Probe installation clearance: 2.50mm (100mil). l Frequency response:0~8KHz, typical value of 0~-3dB, 300m (1000 feet) field wiring. l Power supply:DC supply: -24VDC (-23~-26VDC);Power consumption: current consumption is no more than 20mA. l  Requirements for target:Diameterof target (width of toroid): 30mm (1.2in) not less than 2 times of diameter of probe head; calibrate it on site if the detected surface is small.Shaft diameter: minimum 76mm (3in), 150mm (6in) recommend; pay attention to installation distance between probes to avoid mutual effect when diameter is less than 76mm, and ensure the distance is no less than 65mm (2.6in).Calibration of target material: 40CrMo steel/AISI4140 steel; calibrate it if the target material is inconsistent. l Interchangeability error:Error of interchangeable probe of the same type is ≤±5%;Error of interchangeable extension cable of the same type is ≤±5%;Error of interchangeable proximitor of the same type is ≤±5%; l Field wiring:Using0.5~1.5mm2 three-core shield cable; distance between proximitor and probe is less than 300m (1000 feet). When using a longer cable, signal suffers from attenuation, which needs calibration on site. l Environmental limitations:Probe and extension cable:Probe head pressure: less than 12MPaTemperature: -50℃~+170℃(-58oF~+338 oF)Working medium: air, oil, water, ammonia hydroxide.        Proximitor:Temperature: -35℃~+85℃(-31oF~+185 oF)  Relative humidity: 0~95% (non-condensing) l Physical characteristics:Probe head material: PPS - PPS engineering plastics material resistant to high temperature;Probe housing material: AISI 304 stainless steel (SST);Probe housing torque: standard directly installed probe: 15N.mReversely installed probe: 7.5 N.mExtension cable: 75Ω coaxial cable (covered by fluoroplastic insulating sheath);Armoring of probe and extension cable: 304 SST stainless steel;Proximitor material: A308 aluminum;System length: 5m or 9m including extension cable;Minimum turn radius of cable: 25mm (1in);Connector material: gold-plated brass. l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP65;Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4 Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.3. Ordering information l AN1808 8mm standard proximity probe Metric system: AN1808/M   M10x1 threadAN1808/M-AXX-BXX-CXX-DXX-EXXBritish system: AN1808/I   3/8″-24UNF threadAN1808/I-AXX-BXX-CXX-DXX-EXXStandard model:AN1808/M-00-05-10-00-00AN1808/M-00-05-50-00-00AN1808/M-00-05-90-00-00AN1808/I-00-05-10-00-00AN1808/I-00-05-50-00-00AN1808/I-00-05-90-00-00A: Unthreaded length00—0mm / 0 in05—5mm/ 1/4 in10—10mm/ 1/2 inIncrease by 10mm (0.5in) progressively when placing an order.Max. unthreaded length shall be 200mm/8in less than length of probe housing;Min. unthreaded length is 0, max. housing length minus 1in;B: Total housing length (including unthreaded length):05—50mm / 2 in10—100mm/4 in03-30mm/ 1.2in (housing size of reversely installed probe)Total housing length is increased by 10mm/0.5in progressively;Max. housing length is 250mm/10in and min. is 25mm/1in.C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - Unarmored01 - ArmoredE: Approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Otherl AN1808 8mm reversely installed proximity probe Metric system: AN1808/MR M10x1 thread; unthreaded length: 5mm; total housing length: 30mm.AN1808/MR-05-30-CXX-DXX-EXXBritish system: AN1808/IR 3/8″-24UNF thread; unthreaded length: 0.2in; total housing length: 1.2in.AN1808/IR-02-12-CXX-DXX-EXXStandard model:AN1808/MR-05-30-10-00-00AN1808/MR-05-30-50-00-00AN1808/MR-05-30-90-00-00AN1808/IR-02-12-10-00-00AN1808/IR-02-12-50-00-00AN1808/IR-02-12-90-00-00C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - Unarmored01 - ArmoredE: Approval institution00-No requirement01-ATEX: Ⅱ1 G Exia ⅡC T4XX - Other l AN1800 8mm proximitorAN1800-08-BXX-CXX-DXXStandard model:AN1800-08-05-00-00AN1800-08-09-00-00B: total cable length (probe + extension cable)05—5m09—9mC: installation mode00 - DIN35mm guide rail installation01 –Base plate installationD: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other l AN1880 extension cableAN1880-AXX-BXX-CXXStandard model:AN1880-40-00-00AN1880-80-00-00A:Cable length40—4m45—4.5m80—8m85—8.5mB: Cable options00 - Unarmored01 - ArmoredC: Approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN1825
担保机构: Sensor system Components of AN1825 25mm proximity Sensor system:l AN1825  Probe ;l AN1880 Extension cable;l AN1800 25mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conducto... 还款方式: Sensor system Components of AN1825 25mm proximity Sensor system:l AN1825  Probe ;l AN1880 Extension cable;l AN1800 25mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surface. It can notonly be used for static (shaft position) signal measurement, but also used for dynamic (shaft vibration) signal measurement. It is mainly usedfor the shaft vibration, shaft displacement, key phase, speed and eccentricity of film sliding bearing rotating machinery.AN1825 25mmproximity   Sensor system follows the 670 Standard made by American Petroleum Institute (API) for this kind of Sensor completely. All AN1825 25mm proximity   Sensor systems can reach specified performance criteria and the probes, extension cables and proximitors are fully interchangeable, no independent matching or calibration is required. TheSensor system is safe and explosion-proof in essence and it will not cause spark under electrical operation.Proximitor AN1825 25mmproximitor has two types of mounting base plate. It can select DIN35mm guide rail or traditional panel for mounting. The base plate is insulating when either kind of mounting method is adopted and no separate insulating plate is required.AN1825 25mmproximitor housing is cast from aluminum. To shield external interference, the housing and the signal public terminal (signal earth) are connected inside the proximitor. As the mounting base plate and guide rail seat are made of insulating engineering plastics, it can be ensured that the proximitor housing and earth are isolated when a proximitor is mounted, the radio interference resistance ability is improved and the European RFI/EMI anti-radiation standards can be reached.AN1825 25mm proximitor uses Spring Loc terminal which can be fixed automatically, and wiring can be realized without erecting tools. Besides, it will not get loose for boltfixing is not required.Fault toleranceof AN1825 25mm proximitor: any wiring fault of supply terminal, common terminal (SG) and output terminal can not damage the proximitor, and it has the function of power polarity error protection and output short-circuit protection.Probe and extension cable Allparts of AN AN1825 25mm probe are connected through mechanical deformation to ensure its stability and reliability in severe environment.For all connectors of AN1825 25mm probe and AN1880 extension cable, gold-plated copper connectors are adopted as per MIL-C-39012 (the military specification ofthe U.S.). These connectors only need to be fixed manually (connectors can be locked automatically), and special mechanical locking device can prevent loose connection.Connectors at two ends of AN1880 extension cable are different. The connector with male thread (adapter) is coupled to probe, while the connector with female thread is coupled to proximitor. Fluoroplastics resistant to highand low temperature and chemical corrosion are used for cable insulation and sheath.2. Technical Specificationsl Linear range: 12.5mm (500mil)Linear range is from the position about 2mm (80mil) from surface of the target: 2~14.5mm (80~580mil). l Sensitivity: 0.787mV/μm (20mV/mil)Thesensitivity is less than 0.787mV/μm (20mV/mil) ±5% within the linear range of 12.50mm (500mil) including interchangeability error. l Probe installation clearance: 8mm (320mil). l Frequency response:0~3KHz, typical value of 0~-3dB, 300m (1000 feet) field wiring. l Power supply:DC supply: -24VDC (-23~-26VDC);Power consumption: current consumption is no more than 20mA.l  Requirements for target:Diameterof target (width of toroid): 60mm (2.4in) not less than 2 times of diameter of probe head; calibrate it on site if the detected surface is small.Calibration of target material: 40CrMo steel/AISI4140 steel; calibrate it if the target material is inconsistent.l Interchangeability error:Error of interchangeable probe of the same type is ≤±5%;Error of interchangeable extension cable of the same type is ≤±5%;Error of interchangeable proximitor of the same type is ≤±5%;l Field wiring:Using0.5~1.5mm2 three-core shield cable; distance between proximitor and probe is less than 300m (1000 feet). When using a longer cable, signal suffers from attenuation, which needs calibration on site.l Environmental limitations:Probe and extension cable:Probe head pressure: less than 12MPaTemperature: -50℃~+170℃(-58oF~+338 oF)Working medium: air, oil, water, ammonia hydroxide.Proximitor:Temperature: -35℃~+85℃(-31oF~+185 oF)  Relative humidity: 0~95% (non-condensing) l Physical characteristics:Probe head material: PPS - PPS engineering plastics material resistant to high temperature;Probe housing material: AISI 304 stainless steel (SST);Probe housing torque: standard directly installed probe: 15N.mReversely installed probe: 7.5 N.mExtension cable: 75Ω coaxial cable (covered by fluoroplastic insulating sheath);Armoring of probe and extension cable: 304 SST stainless steel;Proximitor material: A308 aluminum;System length: 5m or 9m including extension cable;Minimum turn radius of cable: 25mm (1in);Connector material: gold-plated brass.l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP65;Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4 Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.3. Ordering information l AN1825 25mm standard proximity probe Metric system: AN1825/M   M30x2 threadAN1825/M-AXX-BXX-CXX-DXX-EXXBritish system: AN1825/I   11/4″-12UNF threadAN1825 /I-AXX-BXX-CXX-DXX-EXXStandard model:AN1825 /M-00-05-10-00-00AN1825 /M-00-05-50-00-00AN1825 /M-00-05-90-00-00AN1825 /I-00-05-10-00-00AN1825 /I-00-05-50-00-00AN1825 /I-00-05-90-00-00A: Unthreaded length00—0mm / 0 in05—5mm/ 1/4 in10—10mm/ 1/2 inIncrease by 10mm (0.5in) progressively when placing an order.Max. unthreaded length shall be 200mm/8in less than length of probe housing;Min. unthreaded length is 0, max. housing length minus 1in;B: Total housing length (including unthreaded length):06—60mm / 2 in10—100mm/4 inTotal housing length is increased by 10mm/0.5in progressively;Max. housing length is 250mm/10in and min. is 25mm/1in.C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - Unarmored01 - ArmoredE: Approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Otherl AN1825  25mm Side entry cable proximity probe AN1825 /S; unthreaded; Clamp is installed; total housing length: 30mm.AN1825 /S-05-30-CXX-DXX-EXX Standard model:AN1825 /S-05-30-10-00-00AN1825 /S-05-30-50-00-00AN1825 /S-05-30-90-00-00A: Unthreaded length05—5mm/ 1/4 in10—10mm/ 1/2 inIncrease by 10mm (0.5in) progressively when placing an order.Max. unthreaded length shall be 20mm/0.8in less than length of probe housing;Min. unthreaded length is 0, max. housing length minus 1in;B: Total housing length (including unthreaded length):05—50mm / 2 in10—100mm/4 inTotal housing length is increased by 10mm/0.5in progressively;Max. housing length is 250mm/10in and min. is 25mm/1in.C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - Unarmored01 - ArmoredE: Approval institution00-No requirement01-ATEX: Ⅱ1 G Exia ⅡC T4XX – Otherl AN1800 25mm proximitorAN1800-25-BXX-CXX-DXXStandard model:AN1800-25-05-00-00AN1800-25-09-00-00B: total cable length (probe + extension cable)05—5m09—9mC: installation mode00 - DIN35mm guide rail installation01 – Base plate installationD: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other l AN1880 extension cableAN1880-AXX-BXX-CXXStandard model:AN1880-40-00-00AN1880-80-00-00A: cable length40—4m45—4.5m80—8m85—8.5mB: cable options00 - Unarmored01 - ArmoredC: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN1850
担保机构: Sensor system Components of AN1850 50 mm proximity Sensor system:l AN1850  Probe ;l AN1880 Extension cable;l AN1800 50mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor su... 还款方式: Sensor system Components of AN1850 50 mm proximity Sensor system:l AN1850  Probe ;l AN1880 Extension cable;l AN1800 50mm proximitor.  Sensorsystem output is proportional to the voltage signal changing with the gap between the probe end and the measured conductor surface. It can notonly be used for static (shaft position) signal measurement, but also used for dynamic (shaft vibration) signal measurement. It is mainly usedfor the shaft vibration, shaft displacement, key phase, speed and eccentricity of film sliding bearing rotating machinery.AN185050 mm proximity   Sensor system follows the 670 Standard made by American Petroleum Institute (API) for this kind of Sensor completely. All AN1850 50 mm proximity   Sensor systems can reach specified performance criteria and the probes, extension cables and proximitors are fully interchangeable, no independent matching or calibration is required. The Sensor system is safe and explosion-proof in essence and it will not cause spark under electrical operation.Proximitor AN185050 mm proximitor has two types of mounting base plate. It can select DIN35mm guide rail or traditional panel for mounting. The base plate is insulating when either kind of mounting method is adopted and no separate insulating plate is required.AN185050 mm proximitor housing is cast from aluminum. To shield external interference, the housing and the signal public terminal (signal earth) are connected inside the proximitor. As the mounting base plate and guide rail seat are made of insulating engineering plastics, it can be ensured that the proximitor housing and earth are isolated when a proximitor is mounted, the radio interference resistance ability is improved and the European RFI/EMI anti-radiation standards can be reached.AN1850 50 mm proximitor uses Spring Loc terminal which can be fixed automatically, and wiring can be realized without erecting tools. Besides, it will not get loose for boltfixing is not required.Fault toleranceof AN1850 50 mm proximitor: any wiring fault of supply terminal, commonterminal (SG) and output terminal can not damage the proximitor, and ithas the function of power polarity error protection and output short-circuit protection.Probe and extension cable Allparts of AN AN1850 50 mm probe are connected through mechanical deformation to ensure its stability and reliability in severe environment.For all connectors of AN1850 50 mm probe and AN1880 extension cable, gold-plated copper connectors are adopted as per MIL-C-39012 (the military specification ofthe U.S.). These connectors only need to be fixed manually (connectors can be locked automatically), and special mechanical locking device can prevent loose connection.Connectors at two ends of AN1880 extension cable are different. The connector with male thread (adapter) is coupled to probe, while the connector with female thread is coupled to proximitor. Fluoroplastics resistant to highand low temperature and chemical corrosion are used for cable insulation and sheath.2. Technical Specificationsl Linear range: 25mm (1in)Linear range is from the position about 3mm (120mil) from surface of the target: 3~28mm (120~1100mil). l Sensitivity: 0.394mV/μm (10mV/mil)Thesensitivity is less than 0.394mV/μm (10mV/mil) ±5% within the linear range of 25.0mm (1000mil) including interchangeability error. l Probe installation clearance: 16mm (640mil). l Frequency response:0~3KHz, typical value of 0~-3dB, 300m (1000 feet) field wiring. l Power supply:DC supply: -24VDC (-23~-26VDC);Power consumption: current consumption is no more than 20mA. l  Requirements for target:Diameterof target (width of toroid): 100mm (4in) not less than 2 times of diameter of probe head; calibrate it on site if the detected surface is small.Calibration of target material: 40CrMo steel/AISI4140 steel; calibrate it if the target material is inconsistent. l Interchangeability error:Error of interchangeable probe of the same type is ≤±5%;Error of interchangeable extension cable of the same type is ≤±5%;Error of interchangeable proximitor of the same type is ≤±5%; l Field wiring:Using0.5~1.5mm2 three-core shield cable; distance between proximitor and probe is less than 300m (1000 feet). When using a longer cable, signal suffers from attenuation, which needs calibration on site. l Environmental limitations:Probe and extension cable:Probe head pressure: less than 12MPaTemperature: -50℃~+170℃(-58oF~+338 oF)Working medium: air, oil, water, ammonia hydroxide.Proximitor:Temperature: -35℃~+85℃(-31oF~+185 oF)  Relative humidity: 0~95% (non-condensing) l Physical characteristics:Probe head material: PPS - PPS engineering plastics material resistant to high temperature;Probe housing material: AISI 304 stainless steel (SST);Probe housing torque: standard directly installed probe: 45N.mReversely installed probe: 10 N.mExtension cable: 75Ω coaxial cable (covered by fluoroplastic insulating sheath);Armoring of probe and extension cable: 304 SST stainless steel;Proximitor material: A308 aluminum;System length: 5m or 9m including extension cable;Minimum turn radius of cable: 25mm (1in);Connector material: gold-plated brass.l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP65;Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4 Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.3. Ordering information l AN1850 50 mm standard proximity probe Metric system: AN1850 /M   M14x1.5 threadAN1850 /MR-AXX-BXX-CXX-DXX-EXXBritish system: AN1850 /I   1/2″-20UNF threadAN1850 /IR-AXX-BXX-CXX-DXX-EXXStandard model:AN1850 /MR-01-05-10-00-00AN1850 /MR-01-05-50-00-00AN1850 /MR-01-05-90-00-00AN1850 /IR-01-05-10-00-00AN1850R /I-01-05-50-00-00AN1850R /I-01-05-90-00-00A: Unthreaded length01—10mm / 1/2 in02—20mm/ 1inIncrease by 10mm (0.5in) progressively when placing an order.Max. unthreaded length shall be 20mm/0.8in less than length of probe housing;Min. unthreaded length is 10, max. housing length minus 1in;B: Total housing length (including unthreaded length):05—50mm / 2 in10—100mm/4 inTotal housing length is increased by 10mm/0.5in progressively;Max. housing length is 250mm/10in and min. is 25mm/1in.C: Total probe length05-0.5m (1.6 feet)10-1m (3.3 feet)50-5m (16.4 feet)90-9m (29.5 feet)D: Cable options00 - Unarmored01 - ArmoredE: Approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other l AN1800 50mm proximitorAN1800-50-BXX-CXX-DXXStandard model:AN1800-50-05-00-00AN1800-50-09-00-00B: Total cable length (probe + extension cable)05—5m09—9mC: Installation mode00 - DIN35mm guide rail installation01 – Base plate installationD: Approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other l AN1880 extension cableAN1880-AXX-BXX-CXXStandard model:AN1880-40-00-00AN1880-80-00-00A: cable length40—4m45—4.5m80—8m85—8.5mB: cable options00 - Unarmored01 - ArmoredC: approval institution00 - No requirement01 - ATEX: Ⅱ1 G Exia ⅡC T4XX – Other
项目规模: 0 项目期限: 0 个月 年化收益:
项目名称: AN1910
担保机构: AN1910magneto-resistive speed sensor adopts high sensitivity magneto -resistive elements and is embedded with magnetic sensitive elements to implement non-contact speed measurement. As the measured object moves, the sensor outputs square wave level signals that change with rotational frequ... 还款方式: AN1910magneto-resistive speed sensor adopts high sensitivity magneto -resistive elements and is embedded with magnetic sensitive elements to implement non-contact speed measurement. As the measured object moves, the sensor outputs square wave level signals that change with rotational frequency ratio.  The two-channel sensor outputs two-channel square wave (TTL level) signals with a phase difference, based on which the running direction of equipment can be determined.2. Functionsl Theobject of measurement is a rotary ferromagnetic material body, including gears, racks, cams and special male and female faces;l Squarewave pulse (TTL level) signals are output, which change with the clearance of magnetic conductive material and magnetic material (fluted disc and key slot, etc.);l The sensor applies to precision measurement of speed (positive and negative operation).3. Featuresl Non-contactmeasurement; the installation clearance is larger than that of common magneto-electric speed sensors and eddy-current sensors (0-5mm);l Embeddedwith high-sensitive magneto-resistive elements, through which square wave signals are output directly, and high immunity from environmental disturbance is realized;l Short-circuit protection and polarity protection;l Fully sealed structural design; capable of working under water and oil.4. ApplicationSpeedmeasurement of various large rotary machines (steam turbines, fans, pumps, compressors, centrifugal machines, and water turbines, etc).5. Technical Specificationsl Frequency range:Single channel: 0 ~ 30KHz Double channel: 0 ~ 10KHzl Output signal: Appropriateto TTL level signals; high-level voltage is similar to supply voltage (VT), while low level is not greater than 0.3V.l Power supply:Voltage: 5 ~ 28VDC (recommended: 12VDC);Power consumption: ≤10mA.l Physical property:Mounting thread:Single channel: M10×1  Double channel: M16×1 (customizable);Bearing length:Single channel: 50mm  Double channel: 75mm (customizable);Installation clearance: Single channel: 1.5mm;Double channel: 2.5mm;Weight: 100g (excluding cables and lengthened type).l Outlet method:Single channel: Direct outlet, 3-core (power supply, common and signal terminals);Double channel: 4-core aviation plug output (power supply, common, signal A and signal B terminals).l Environmental restrictions:Temperature: -40℃ ~ +75℃ (- 40oF ~ +167 oF)Can work under oil and water.l Executive standardsThe United States Petroleum Association Standard: API 670Safety certificate: CE;Protection level: IP65;Explosive-proof grade: ATEX: Ⅱ2G ExdⅡCT4/BT4 Anti-electromagnetic interference: EMC/LVDRefer to EN55011\ EN 61010\ EN50081\EN50082.6. Ordering information   AN1912--Double channel, metric M16X1 mounting threads;   AN1911--Single channel, metric M10X1 mounting threads, direct outlet;     AN1911- AXX-BXX-CXX-DXX-00-FXX     AN1912- AXX-BXX-CXX-DXX-EXX-FXXStandard model:     Single channel: AN1911--05-05-05-00-00-00     Double channel: AN1912--05-07-05-01-01-00A: Unthreaded length:05--5mmIncreased by 5mm (0.1in) on order;Maximum unthreaded length is 20mm/0.8in less than probe bearing;Minimum unthreaded length is 0mm; maximum unthreaded length: 200mm (8in).B: Threaded bearing length:05--50mm07--75mmOverall bearing length is increased by 5mm/0.1in;Overall bearing length is 250mm/10in maximally, and 25mm/1in minimally.C: Cable length03--3m05--5mxx--OthersD: Outlet method:00--Direct outlet01--Aviation plug outletE: Armoured00—Unarmoured01--ArmouredF: Environmental restrictions00--No requirement01--Anti-hazard ATEX: Ⅱ1 G Exia ⅡC T4
项目规模: 0 项目期限: 0 个月 年化收益: